
Open
Posted
•
Ends in 9 hours
Paid on delivery
***PM me examples of this work if bidding*** We are looking for a qualified building physics/thermal consultant to carry out a project-specific U-value calculation and interstitial condensation risk assessment for a timber-frame wall system in Ireland. Wall system includes: 600 mm stud centres 140 mm λ0.032 wool insulation OSB sheathing Kingspan ThermaBoard TF70/TP10 PIR – 50, 70, 80 & 100 mm options 35 mm external battens Breather membrane Ventilated external cavity Internal airtightness/vapour-control membrane Plasterboard We require: Accurate U-value for each wall option Interstitial condensation/moisture risk assessment Thermal bridging/timber fraction taken into account Assessment to relevant Irish/European standards Professional calculation report suitable for inclusion in our technical/compliance documentation.
Project ID: 40744130
5 proposals
Open for bidding
Remote project
Active 4 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
5 freelancers are bidding on average €44 EUR for this job

With my extensive background in Physics and working knowledge of Mathematics, I am uniquely qualified to handle the complexities of your U-value calculation and interstitial condensation risk assessment project. My in-depth understanding of subjects like Heat, Thermodynamics, and Fluid Dynamics aligns perfectly with what the task requires. I have prior experience conducting similar analyses and generating the comprehensive, professional reports that you require for technical compliance documentation. Not only am I skilled in using software such as OriginPro for scientific data analysis and visualization, but also well-versed in industry standards pertaining to thermal assessments and moisture risk calculations within building science. My familiarity with materials like OSB sheathing and insulation options such as Kingspan ThermaBoard TF70/TP10 PIR equips me with a practical understanding of the challenges that might arise during the process. Moreover, my proficiency in research paper writing, thesis editing, technical documentation, and data analysis can be especially useful during this project's lifecycle. With these skills combined with my reputation for delivering high-quality work on time, I'm confident that I offer the expertise necessary to accomplish all your project goals efficiently.
€50 EUR in 1 day
5.7
5.7

Greetings, Since you require a U-value assessment of the given wall design, I would be able to carry out the calculations based on my relevant background. All the calculations would be summarized in the report for clarity. Besides, moisture risk assessment could be included as per Irish standards. In the end, there will be a clear conclusion for you to decide what to do with it as a result of my submission. Please ask for the samples upon your answer in the chat box. Regards
€30 EUR in 1 day
4.7
4.7

Hi there, I am a building physics consultant with extensive experience delivering BS EN ISO 6946 U-value calculations and BS EN ISO 13788 Glaser method interstitial condensation risk assessments for timber-frame construction across Ireland and the UK. I can model all four Kingspan ThermaBoard TF70/TP10 PIR thickness options (50 mm, 70 mm, 80 mm, and 100 mm) taking into account: Precise timber fraction adjustments for 600 mm stud centers (combining insulation λ0.032 W/mK and C16/C24 stud framing). Resistances for the ventilated cavity, 35 mm battens, breather membrane, OSB sheathing, VCL, and plasterboard layers. Hygrothermal risk analysis across seasonal boundary conditions for Irish climate data. You will receive a comprehensive, compliance-ready technical report formatted specifically for inclusion in your Irish Building Regulations (Part L) documentation. Kindly get in touch so that I can send you examples of my previous timber-frame thermal and moisture assessment reports directly via PM. I can start immediately and deliver the complete report within 24–48 hours. Let's discuss your preferred boundary conditions so I can get started. Best regards,
€56 EUR in 7 days
4.4
4.4

Hi, how are you doing? I can provide a project-specific thermal assessment for your timber-frame wall build-up, including U-value calculations and interstitial condensation risk analysis for each PIR thickness option. I will evaluate the 50, 70, 80, and 100 mm Kingspan configurations while accounting for the timber stud fraction, insulation conductivity, OSB, battens, ventilated cavity, membranes, plasterboard, and other relevant layers. The analysis can include condensation risk through the assembly, vapour-pressure behaviour, and the effect of thermal bridging through the timber framing. I can prepare the calculations in line with the applicable Irish and European methodology and present the assumptions, material properties, calculation steps, and results clearly in a professional report. The final report can compare all four wall options side by side so you can see the resulting U-values and moisture-performance differences. I can also flag any build-up that presents an elevated condensation risk and identify practical changes to improve performance where necessary. Please send the exact layer thicknesses, timber stud dimensions, membrane product data, OSB thickness, plasterboard type, and any project-specific indoor/outdoor design conditions you want used, and I can start immediately. Thank you, Uzair
€50 EUR in 3 days
0.0
0.0

Donegal, Ireland
Payment method verified
Member since Jan 14, 2015
€8-30 EUR
€30-250 EUR
$10-30 USD
€30-250 EUR
€30-250 EUR
$25-50 USD / hour
$250-750 USD
$250-750 AUD
$30-250 USD
$250-750 USD
$250-750 CAD
$10-30 USD
€8-30 EUR
$10-30 USD
$300 CAD
$25-50 USD / hour
$30-250 USD
₹12500-37500 INR
$250-750 USD
£10-15 GBP / hour
$5000-10000 USD
£750-1500 GBP
£250-750 GBP
₹17000 INR
₹12500-37500 INR