Land Details:
1. Details of the land is given in the attached drawing.
2. In the drawing you will find a Contour survey or topography of the plot (which differs from actual area on map).
3. In the drawing you will also find a drawing with actual plot details.
4. In the above drawing you will find that area at the back is left as green area, you have to leave this area as green area for the project. Additional green area can be left as per the plan.
5. In the front side you will find that some area is affected under road widening. This area needs to be deducted from the actual area.
6. Area on the map is more than the actual area which is 3890 sq. mtr and after deduction of area under road it is 3569 sq. mtr.
7. 321 sq. mtr of land is coming under road width. we will get double FAR for the this area. this can also be understood from the table shown in the drawing.

Requirements:
1. I need a concept drawing (Autocad) for a residential cum commercial project.
2. The commercial portion may cover the entire ground floor or some part of both ground and first floor.
3. Keep the total commercial area to around 10000 square feet.
4. Commercial area per office/shop should not exceed 400 square feet.
5. Commercial space must have at least one Toilet.
6. No lift is needed in commercial Area.
7. Residential area should comprise of 2 & 3 BHK apartments.
8. 2 BHK with a built up area of around 850 sq ft. and 3 BHK of around 1050 sq. ft.
9. A small club house of around 2000 sq ft. which should have a Gym , table tennis etc.

By Laws:
1. Maximum Ground Coverage should not exceed 30% of the plot area.
2. For a building of height 18m, setback of 6m is to be left all around the building except at the front where the setback should be half of the building height.
3. For a building of height 21m, setback of 7m is to be left all around the building except at the front where the setback should be half of the building height.
4. Floor area ratio allowed is 1.75

Parking Norms:
1. One car parking space for every 125 sq. mtr of Residential Built up area.
2. One car park space for every 75 sq. mtr of Commercial Built up area.
3. Area required for one car park (including circulation space) in :
Basement : 35 [login to view URL]
Stilt / Podium : 30 Sq. mtr
Open : 25 [login to view URL]
4. Height of Basement / Stilt / Podium parking should not exceed 8 feets

Important Note:

1. Land is around 6 - 9 feet down from the adjoining road. This level difference is to be used for basement parking.
2. 6 mtr clear space is to be kept around the building, space after 6m can be used for open parking.


For any other query.. you can contact me on my email: [login to view URL]@[login to view URL]

Anbefalede Evner

Arbejdsgiverfeedback

“Awesome experience.. Great Work,...”

Profilbillede ankur26384, India.

Offentlig Præciserings Opslagstavle

  • beehive3dworks
    beehive3dworks
    • 4 år siden

    Can u please seal the contest...

    • 4 år siden
    1. beehive3dworks
      beehive3dworks
      • 4 år siden

      The ground coverage includes builtup area on ground and does not include projections above 2.5 mts... Neither does it include service ducts, lift ducts . So I have not exceeded the ground coverage by 30 % .. Will upload final dwgs soon

      • 4 år siden
    2. ankur26384
      Konkurrenceafholder
      • 4 år siden

      I am still not sure about it. It wud be great if you can give me a call today itself on my number 9753730000 and explain me so that I can award you the contest.

      • 4 år siden
  • arup1971
    arup1971
    • 4 år siden

    Ankur you can check my entry no 21 as that has a clearer and improved image.

    • 4 år siden
  • beehive3dworks
    beehive3dworks
    • 4 år siden

    Hi Ankur, ...Thanks for extending the deadline..I will upload my design entry soon

    • 4 år siden
  • arup1971
    arup1971
    • 4 år siden

    Hi Ankur... I am again working on this layout design and trying to prepare something spectacular for you. Shall hope to upload by midnight today.

    • 4 år siden
  • wrishitesh
    wrishitesh
    • 4 år siden

    Hello Ankur, can it be more than one building or it needs to be single? Thanks.

    • 4 år siden
    1. wrishitesh
      wrishitesh
      • 4 år siden

      Thanks for extending the contest.

      • 4 år siden
    2. ankur26384
      Konkurrenceafholder
      • 4 år siden

      waiting for your entry

      • 4 år siden
  • bernatolentino
    bernatolentino
    • 4 år siden

    Thanks for the invitation.

    • 4 år siden
  • crystalARCH
    crystalARCH
    • 4 år siden

    Thanks for your invitation.

    • 4 år siden
  • basitsiddiqui
    basitsiddiqui
    • 4 år siden

    Hi Dear, Can you make this contest Guaranteed.

    • 4 år siden
    1. rmissin
      rmissin
      • 4 år siden

      It tells you right next to the button...

      "Guarantee freelancers that a winner will be chosen and awarded the prize. This will attract better entries from more freelancers. Moneyback guarantee is not applicable if a contest has a guaranteed upgrade."

      • 4 år siden
    2. ankur26384
      Konkurrenceafholder
      • 4 år siden

      i have made the contest guaranteed.

      • 4 år siden
  • arup1971
    arup1971
    • 4 år siden

    Hello Ankur
    Let me get this clear before I begin drafting your requirements. You have a site plan drawing but want us to fill in the drawing with Bldg Layouts of blocks as specified by you. All your requirements must be shown in the drawing following the By laws as specified. I guess a new housing complex is going to come up on this plot of land.

    • 4 år siden
    1. ankur26384
      Konkurrenceafholder
      • 4 år siden

      you are right dear. The only thing u have to keep in mind is the area in the site plan is little more than that on records. So kindly consider the area on record for Ground coverage and FAR calculations.

      • 4 år siden
  • wrishitesh
    wrishitesh
    • 4 år siden

    Also, what is the max. ht. possible for the plot? plz let me know. Thanks.

    • 4 år siden
    1. ankur26384
      Konkurrenceafholder
      • 4 år siden

      upto 10 floors.. but i wud like u to end it at 6 floors or a max of 7

      • 4 år siden
  • ankit1241993
    ankit1241993
    • 4 år siden

    Am I supposed to draw the residential building on the drawing that is to the left of the topography plot?

    • 4 år siden
    1. ankur26384
      Konkurrenceafholder
      • 4 år siden

      the plot size on that drawing may be more than the actual area i.e. 3890 sq. mtr before deducting the road width.

      • 4 år siden
    2. ankur26384
      Konkurrenceafholder
      • 4 år siden

      so use 30% ground coverage on (3890 - road width area) i.e. 3569 sq.m. so maximum ground coverage should not exceed 1071 sq.m

      • 4 år siden

Vis flere kommentarer

Sådan kommer du i gang med konkurrencer

  • Opret din konkurrence

    Opret din konkurrence Hurtigt og nemt

  • Få tonsvis af indlæg

    Få tonsvis af indlæg Fra hele verden

  • Tildel det bedste indlæg

    Tildel det bedste indlæg Download filerne - Nemt!

Opret en Konkurrence Nu eller slut dig til os i dag!